Will humidity damage the transmitter?
Humidity is a risk only when the enclosure does not meet the requirement for the given place. The InnerWeb industrial beacon holds approvals covering IP testing, so the water protection requirement is verified with a document, not with a promise.
The practical problem is condensation. In places where the transmitter is alternately warm and cold, such as at cold store doors and in transition zones, water condenses on the outside of the enclosure. Choosing an IP code with a margin and checking the seals during inspections solves most of the problems.
During an inspection, look for signs of corrosion on the mounting elements, because these usually age faster than the enclosure itself.
How does dust affect the operation of the transmitter?
A dust tight enclosure, meaning a first IP digit of 6 according to IEC 60529, does not let dust into the interior. Dust settled on the outside does not disturb radio transmission, but a layer on the enclosure makes visual inspection and identification of the device harder.
In halls with heavy dust, the position of the network relative to combustible dust also matters. If the zone is classified as hazardous because of dust, a transmitter with ATEX certification for zone 22 is needed. The InnerWeb beacon has such certification for zones 2 and 22.
Calibrating the transmission power to the hall reduces interference, and many transmitters in dusty areas should not transmit at factory power if the hall is small.
Indicative network maintenance cost over one year
What happens to transmitters in frost?
Low temperature affects mainly the batteries, because their instantaneous capacity drops. For this reason battery life is not given as a guarantee, and the planning of replacements is based on power calibration and on monitoring of correct operation.
In the network maintenance offer, battery replacement is part of the service, and monitoring shows which points need attention. You therefore do not wait for a failure, but plan the visit together with the inspection.
For a cold store project, ask the supplier three questions: what temperature range follows from the device documentation, how often battery checks are recommended in this environment, and whether the IP rating takes condensation into account.
- Operating temperature from the device documentation.
- Frequency of battery checks in the cold.
- Condensation at doors and in transition zones.
Does the network have to be switched off while batteries are replaced?
There is no need for that. The transmitters are battery powered, with no intervention in the electrical installation, and the replacement is carried out point by point as part of the maintenance service. Plant traffic and alarms keep working, because the other transmitters remain visible to phones.
The position of a person results from the signals of several transmitters averaged on the map, not from a single strongest one. The temporary absence of one point does not wipe out the location, which matters during planned service visits.
What does it cost to maintain transmitters in a harsh environment?
The indicative maintenance cost is PLN 7 net per unit per month. These are indicative ranges from deployments in 2025 and 2026, and the price is quoted individually. The service covers battery replacement, monitoring of correct operation and ongoing support.
A harsh environment does not change the cost structure, but it may change the frequency of checks. We show the detailed calculation for 4 years on a separate page about the cost of maintaining the network.
How do you check after installation that the transmitters cope with the hall conditions?
After installation, coverage and power calibration are carried out, and network acceptance takes place before the alarms are switched on. In the first weeks it is worth comparing positions at the most demanding places: at cold store doors, next to conveyors and on the yard.
If a point behaves unstably, the most common cause is its location, not the transmitter itself: a metal structure, a rack screen or too great a distance from a neighbour.
Video
Frequently asked questions
Do transmitters work in a cold store?
Yes, provided the enclosure and the battery checks have been matched to the temperature. Check the requirements in the device documentation and confirm them at acceptance, especially at doors where condensation occurs.
Does combustible dust require separate transmitters?
If the zone is classified as hazardous because of dust, an ATEX version for zone 22 is needed. The InnerWeb beacon is available in a version for zones 2 and 22.
How many years do the batteries last?
We do not give battery life as a guarantee. It depends on transmission power, calibration and temperature, and the replacement is carried out by the maintenance service.
Do transmitters need to be cleaned of dust?
Dust on the outside of the enclosure does not disturb transmission, but it is worth removing it during inspections so that the marking can be read and the condition of the seals assessed.