Who these recommendations are for
The recommendations are for logistics and maintenance managers in warehouses with cooled chambers and freezers, where employees move on foot or by pallet truck and the plant wants to know their location for safety and workflow.
We do not give battery temperature parameters or operating ranges here, because the values depend on the cell used and must come from its specification. We follow the rule that battery life is not promised as a guarantee, and in a cold chamber this applies even more.
Recommendations 1 and 2: temperature requirements and power calibration
First, record the actual temperatures of the chambers, including fluctuations when doors are opened and during defrosting, and pass them to the supplier before the offer. It is a generally known fact that cell capacity drops with temperature, so the battery replacement plan in a cold chamber should be more cautious than in a heated hall.
Second, require power calibration of the transmission to the chamber. Power calibration reduces crosstalk and extends battery operation, and battery life is planned after calibration, not according to factory settings. In a chamber with racks and goods of high humidity, power set too high increases consumption and crosstalk between neighbouring rooms.
Number of transmitters for a chamber (recommendation of 100-200 m² per unit)
- 1 per 100 m²
- 1 per 200 m²
Recommendations 3 and 4: density and position from several transmitters
Take 1 transmitter per 100-200 m² in a building as the starting point and correct it after a test walk. The position results from the signals of several transmitters averaged on the map, not from the strongest one, so in a chamber every point where location is needed should see several transmitters.
Pay attention to the walls and doors of the chambers. Insulated walls, racks with goods and doors can attenuate the signal, so treat neighbouring chambers as separate coverage zones and check the position on the zone boundaries. Location works without GPS, which is an advantage in a closed warehouse, but it does not replace a coverage plan.
Recommendations 5 and 6: installation and servicing in the chamber
Battery power means installation without intervening in the electrical installation: there are no cables through the chamber walls and no penetrations that have to be sealed. This is a real benefit in a chamber, where every penetration is a potential thermal bridge.
Plan servicing so that it does not require a long stay in the freezer chamber. Battery replacement is part of the maintenance service, with monitoring of correct operation and support. For a freezer it is worth agreeing with the supplier on shorter work windows and on early indication of the transmitters to be replaced, based on monitoring.
Recommendation 7: questions for the supplier and a sample calculation
Ask the supplier which cells are used and what their temperature ranges are, how the power calibration procedure in the chamber works, how the battery status is reported, and what the replacement plan is. Ask for written answers, not general declarations.
A sample calculation of the number of units: for a chamber of 1,000, 3,000 or 5,000 m², the recommendation of 1 transmitter per 100-200 m² gives respectively 5-10, 15-30 and 25-50 units. This is the starting point for a quotation, not the final design: the number is corrected by the test walk and the required accuracy.
Number of transmitters for a cooled chamber
| Parameter | Value |
|---|---|
| Chamber area | 3,000 m² |
| Recommended density | 100-200 m² per transmitter |
Result: 15-30 transmitters as the starting point for the quotation
Note: Sample calculation based on the assumptions in the page text; not an offer, individual quotation applies.
Checklist
Video
Frequently asked questions
Do radio beacons work in a cold storage chamber?
The temperature range depends on the cell used and must follow from its specification. Before ordering, the actual chamber temperatures should be passed to the supplier and a written answer obtained.
Is battery operation time in freezing conditions guaranteed?
No. Battery operation time is not given as a guarantee. It is planned after power calibration and verified by monitoring the network status.
How many transmitters does a 3,000 m² chamber need?
According to the recommendation of 1 transmitter per 100-200 m², 15-30 units is the starting point. The final number is set by the test walk and the required accuracy.
Let us review the network plan for cooled chambers
We will go through the chamber temperatures, power calibration and the battery replacement plan with you. The quotation is individual.
Let's talk