Problem: the filter stands outside, but the register says it is the hall
In the old plant register the dust extraction installation had one name and one assignment: to the production hall, because the process chain started there. The geometry looked different: most filters, tanks and fans stood outside the wall. On the map their points fell outside the hall outline, and a line clipped to the inside of the building lost some of its positions.
The administrator had two options: keep the dust extraction as a hall line and accept points outside the outline, or split it into a separate building. The decision is not cosmetic. Dust installations have their own explosion and ignition risks, their own contractors and their own requirements for hot work.
Rule: more than half outside the outline means a separate building
In the rule applied, a dust extraction installation lying more than half outside the production hall outline becomes a separate building 8 m high with the line Main zone. The others, lying mostly inside the hall, remain hall lines.
The half threshold is a convention, but it has one advantage: it can be calculated. For each installation you take the area of its outline or the number of its points and check what share lies outside the wall. The result goes into a review table that the administrator approves before anything is changed in the structure.
- More than half outside the outline: a separate building, 8 m high, line Main zone.
- Half or less outside the outline: a line in the existing hall building.
- The 8 m height is an adopted assumption for the volume; the plant may correct it.
- The decision for each installation is recorded in the review table.
Example: share of installations outside the hall outline
Why a line clipped to the hall is not enough
Child objects of a building live inside the outline reduced by 1 m, the thickness of the wall, and a line with its own shape is clipped to that interior. If a filter stands outside, clipping throws it outside the line, and the location pin ends up in empty space.
A separate building solves this at the geometry level: the object has its own outline, its own volume and its own interior, where lines can be placed freely. For field work the address changes: instead of the hall's process chain, the contractor selects the dust extraction building and a specific location within it.
Effect on permits for high-risk work
A permit for especially hazardous work indicates the location. If the dust extraction is a hall line but the hot work takes place on a filter 40 m from the wall, the person accepting the permit reads an address that does not match the position. With a separate building the address is unambiguous, and the risks can be assigned to a location inside it.
Only the user on the plant side approves or rejects the permit, while the fire watch is carried out by a worker from the external company. Both roles need the same, correct address of the place. A good plant structure therefore works for safety, not only for tidy data.
Conclusions for the head of maintenance
It is worth running the dust extraction review in one sequence: list of installations, position against the outline, table with the half threshold, decision, migration in the test environment, review of the map. The team gets a list that can be shown to an auditor as the justification for the structure.
The most common mistake is moving everything at once. It is better to change a few installations, check the result and only then continue. The plant map is a shared document of production, OHS and external companies.
Example of the half-outline threshold
| Parameter | Value |
|---|---|
| Dust extraction installations in the plant | 5 pcs |
| Threshold for splitting off a building | 50 % outside the outline |
Result: 3 installations above the threshold form a separate building, 2 remain hall lines.
Note: Example calculation; the shares in the chart are assumptions, not a measurement of a specific plant.
Checklist
Video
Frequently asked questions
Should a dust extraction installation always be a separate building?
No. When most of it lies inside the hall, it stays a hall line. A separate building applies to installations standing more than half outside the outline.
What height does the dust extraction building have?
In the adopted rule, 8 m, with the line Main zone. This is an assumption for the volume, which the plant can change after measurements.
What happens to the existing permits?
New permits point to the new address. The permit history is left unchanged, and the mapping of old locations is documented in the review table.
Dust extraction at your plant
Send the layout of the installations against the hall, and we will prepare the decision table and a migration scenario for the structure.
Let's talk