The service crew should replace beacon cells during a shutdown, not while the hall is running. The height and fixing element chosen at the design stage decide this. We collect best practices: where to mount, how to count levels and what to put into the service contract.

about every 4 years
cell replacement included in the subscription in one of the offers
Source: card
2,400 PLN
sample subscription net per month, indicative
Source: card

Why mounting height is a service decision

A beacon works for several years, but its cells have to be replaced eventually. Cell replacement is a service task, and in one of the maintenance offers it was included in the subscription about every 4 years. If a beacon hangs at a height that can only be reached with a lifting platform and while the hall is running, each replacement becomes an operation with risk.

That is why height and fixing element are chosen not only for coverage, but also for service access. This is a decision taken jointly by the integrator, maintenance and occupational health and safety, before the equipment is ordered.

Practice 1: mount on fixed elements

The best places are girders, columns and walls, which do not change their position. A beacon hung on a moving structure or on a cover that is removed no longer matches its record on the map.

Before choosing a point, check whether service access exists during a shutdown: a platform, lockable doors, room for the lifting platform. If not, move the point to an accessible place, keeping the grid.

Components of a sample maintenance subscription (PLN net per month)

Components of a sample maintenance subscription (PLN net per month)Horizontal bar chart: 1,400 PLN for beacons, 800 PLN for server and licences, 200 PLN for watches, 2,400 PLN in total.050010001500PLN200 beacons at 7 PLN200 beacons at 7 PLN: 1400 PLN1400Server and licencesServer and licences: 800 PLN8002 watches at 100 PLN2 watches at 100 PLN: 200 PLN200
Source: Offer card: indicative ranges from implementations in 2025 and 2026; individual pricing applies

Practice 2: count levels and the reserve

Receiving points are counted separately for each level, and a reserve for difficult places is added instead of applying one uniform grid. Mounting at height usually concerns the upper level and the mezzanines.

Mark on the plan the points that cannot be reached without scaffolding, and treat them as reserved for a shutdown. If such a beacon fails, neighbouring points keep the position, because the position is calculated from many beacons.

Practice 3: write the replacement into the service contract

A sample maintenance subscription covered 200 beacons at 7 PLN, a server and licences for 800 PLN, and the rental of 2 watches at 100 PLN each, giving a total of 2,400 PLN net per month. These are indicative ranges from implementations in 2025 and 2026; individual pricing applies.

Pay attention to what such an item covers: cell replacement, replacement of a damaged beacon, a coverage check. It is worth recording that the replacement takes place during a shutdown, not on an arbitrary day.

Practice 4: keep the record up to date after replacement

After replacing a beacon or moving it, update the record in the database and check the route. A beacon recorded in the wrong place draws a route jump, and two physically different beacons with the same identifier are recognised as one entry.

Introduce two control actions after each replacement: a comparison of the physical label with the entry, and a short drive or walk along the route where the point lies. This takes a few minutes and saves hours of diagnosis.

Practice 5: plan the replacement schedule in advance

The choice of broadcast interval affects the date of replacement: 500 ms means 4 to 5 years, 250 ms about 3 years, 150 ms about 2 years. If the plant has a yearly shutdown, set the interval so that the next replacement falls in one of them with a margin.

Group the beacons by height and access, so that one crew with one lifting platform replaces them in one window. A scattered schedule generates more visits than a single action.

Checklist

Video

Frequently asked questions

Does replacing cells require stopping the hall?

It depends on the height and place. For points on platforms and in traffic zones replacement is planned during a shutdown, while easily accessible points can be serviced during operation with the observance of occupational health and safety rules.

How often do the cells need to be replaced?

It depends on the broadcast interval: 4 to 5 years at 500 ms, about 3 years at 250 ms and about 2 years at 150 ms.

Is cell replacement included in the subscription?

In one of the maintenance offers the replacement was included in the subscription about every 4 years. The scope is always agreed individually.

Let us agree on service at the design stage

Talk to the InnerWeb team about the mounting height and the replacement schedule. We will help you put together the scope of the service contract.

Let's talk