InnerWeb
Skip to main content

Major and minor numbering and transmitter names: recommendations for the administrator

A duplicate major:minor pair later costs a site visit and weeks of distrust in the map. A few rules agreed before the first installation are enough to prevent it. Below are seven recommendations for the administrator of the location system at a production plant.

100 m
approximate spacing of transmitters along the plant road
Source: faktografia
100-200 m2
floor area per transmitter in a building
Source: faktografia

For whom and why this list

These recommendations are addressed to the administrator of the location system, who decides before installation at the plant how transmitters are marked in the database. They also concern the integrator and the person responsible for installation documentation, because they are the ones who add further devices years later.

The stakes are concrete. Two physical transmitters several hundred metres apart may broadcast an identical major:minor pair, and the system then recognises them as one transmitter. Routes start to jump, and simply moving the position in the database does not fix the error, it only moves it to the other place.

Seven recommendations

The recommendations are ordered from the most important. The first three concern uniqueness, the next ones names and spares, the last ones checks after installation.

1. Reserve a range of major numbers for each zone

Assign a range of major numbers to each zone of the plant: hall, road, yard, warehouse. This way the number itself tells you where to look for the transmitter, and two devices in different zones cannot receive the same pair by mistake.

Reserve the range with some margin. Extending a hall should not require renumbering the existing devices.

2. Minor rising within a zone, with no reuse of numbers

Assign minor numbers in sequence and do not reuse them after a transmitter is withdrawn. A replaced unit gets a new number, and the old record stays in the database as a spare. Reusing numbers is the shortest path to a duplicate, because the old device may still be mounted somewhere.

3. A transmitter register kept before installation

Before a transmitter leaves the warehouse, enter it in the register: identifier, zone, planned place, installing person. A register generated after the fact always contains gaps. Before the first installation you can also check whether any major:minor pair repeats in the import file.

4. Location name as data, not decoration

The name of a transmitter shown on the map comes from the location assigned to it, not from the transmitter itself. Name locations so that the place of installation is visible: road, section, pole number. Names such as 'Point 1' help no one who is hunting an error at two in the morning.

5. One location, one physical place

One physical navigation point may have two transmitter rows in the database with a shared minor and different majors, of which only one is detected and the other is a dormant spare. Accept such a pair knowingly and describe it in the register, so that nobody corrects the position of the row that is not the live one.

6. Do not delete inactive transmitters

Spare transmitters may start transmitting again someday, so their records stay. To tell the pair apart, a spare may receive a name with a zero appended. It is a simple convention that saves questions during diagnosis.

7. Check after installation, not only before

After installing a batch of transmitters, check on the map whether the routes of a test trip are continuous. This way duplicates surface in the first week, not after a quarter. If a problem is detected, we describe the diagnostic methods in the best practices for detecting duplicates.

Example pool of major numbers by zone (count of numbers)

Example pool of major numbers by zone (count of numbers)Horizontal bar chart: five pools of one hundred major numbers each for halls, roads, yards, warehouses, and test and withdrawn transmitters.020406080100major numbersHallsHalls: 100 major numbers100RoadsRoads: 100 major numbers100YardsYards: 100 major numbers100WarehousesWarehouses: 100 major numbers100Test and withdrawnTest and withdrawn: 100 major numbers100
Source: Example calculation: scheme from the section Sample numbering scheme

Sample numbering scheme

The scheme below is an example, not a standard. Adapt it to the number of zones in the plant. We assume a plant with four zones and a reserve for expansion.

Hall zone: major 100 to 199. Road zone: major 200 to 299. Yard zone: major 300 to 399. Warehouse zone: major 400 to 499. Majors 900 to 999 are kept for test and withdrawn transmitters. Minor rises from 1 within each major, without reuse.

  • Halls: 100-199
  • Roads: 200-299
  • Yards: 300-399
  • Warehouses: 400-499
  • Test and withdrawn: 900-999

Georeferencing and numbering

Numbering solves the question of identity, but the position still requires correct georeferencing of the hall. The physical position of a device is converted to geographic coordinates based on an anchor point, rotation and scale, with a correction for the meridian convergence of the PUWG 1992 system. Omitting the correction shifts the point by tens of metres.

In practice this means that two different errors produce a similar symptom. A route jump may come from a duplicate identifier or from a shifted georeference. Settling the numbering in advance narrows the field of search.

What to avoid

The most common mistakes are copying numbers from an old installation into a new one, assigning majors in the order the equipment was delivered, and describing locations with abbreviations known only to the fitter. Each of them produces either an unreadable database or a duplicate.

Making the scheme overly complicated is also unnecessary. A simple rule that the team actually follows is better than a complicated one that everyone interprets differently.

Video

Frequently asked questions

Is it enough for the major:minor pair to be unique within a zone?

No. The system recognises a transmitter by the pair alone, so it must be unique across the whole installation, including between zones and halls.

Can the numbers of withdrawn transmitters be reused?

We advise against it. The old device may still be mounted or may return to circulation, and reusing a number creates a duplicate.

How do I know what name the user sees on the map?

The name comes from the location assigned to the transmitter. That is why location names should describe the place of installation.

Planning a transmitter installation at your plant?

We will help you settle the numbering scheme before the first installation. Book a conversation with the InnerWeb team.

Let's talk