Pumping station without signal: LoRa SOS for lone work

A technician goes down alone into a sewage pumping station, and the phone has no signal there. This implementation scenario shows how pulses from the active card travel over a LoRa bridge into the same stillness and alarm mechanism that works on sites with Wi-Fi. We describe a concept for a water utility, not a completed installation.

52 s
median closing time of a stillness alarm in a working deployment
Source: internal card
3,400 h
of monitoring in a working stillness detection deployment
Source: internal card
7 in 10
stops are cancelled by the employee alone
Source: internal card

Starting point: a site without connectivity

A sewage pumping station on a rural collector network usually sits where the ground is lowest and furthest from housing. The chamber is partly underground, the cover and walls block mobile signal, and nobody planned for Wi-Fi because the site works without people most of the time. The technician arrives for a few dozen minutes, most often alone.

This is classic lone work in conditions where every minute of delay matters. If something happens, nobody sees it from outside, and the phone cannot send a message or make a call. The dispatcher learns about the problem only when the technician does not return at the planned time.

The concept below is meant for a mid-sized water utility with several dozen such sites that wants the same level of protection on these sites as on the main treatment plant.

What the active card carries and how the signal reaches the system

The active card is worn by the employee and sends a pulse at regular intervals. When the site has no Wi-Fi and no coverage, the pulse travels by radio using the LoRa standard to a LoRa bridge. The bridge translates the frames into the system's existing API, so neither the watch nor the card needs Wi-Fi.

From the platform's point of view, the key point is that pulses from LoRa active cards reach the same stillness mechanism as the data from the mobile app. No separate, parallel alarm system is created. The same thresholds, the same rules and the same notification chain serve an employee with a phone and an employee with a radio card.

Stillness detection works on two sides: the app analyses the device's sensors, and the server measures time independently, and only when both agree is the full alarm triggered. With a LoRa card it is the server that measures the silence of pulses and movement and acts as an independent witness, so the utility does not have to rely on a single source.

  • the active card sends a pulse at regular intervals, without any action by the user
  • the LoRa bridge receives the frames and passes them to the system API
  • the same stillness mechanism serves the LoRa card and the mobile app
  • no Wi-Fi is required on the device worn by the employee

Pattern of warning and alarm times on a watch

Pattern of warning and alarm times on a watchBar chart: 20 seconds to warning, 30 seconds to alarm, median alarm closing time 52 seconds.0204060sNo movement until warning: 20 s20 sNo movement until warningFurther until alarm: 30 s30 sFurther until alarmMedian alarm closing time: 52 s52 sMedian alarm closing time
Source: Pattern of the warning on an LTE watch and data from a working stillness detection deployment

What happens after the threshold is crossed

When the stillness threshold is crossed, the system sends a push notification and an email to the people responsible, creates an alarm permit from the ALARM template, marks the alarm on the map and can trigger an external webhook. When the employee moves again, the alarm permit closes on its own. The dispatcher therefore gets one consistent piece of information: who, where and since when.

The SOS alarm works differently from stillness. It is triggered with a button on the watch: a triple click or a long press, with the option to cancel during a three-second countdown. SOS always creates its own permit and starts the rescue chain, that is the messenger and automatic phone calls, and it stays active until a person closes it. Unlike stillness, it is active and unconditional: it does not depend on the stillness settings or the location configuration, and it does not close itself when movement is detected.

For a pumping station this means two complementary paths. The first works when the employee cannot do anything, because they have lost consciousness or are trapped. The second works when they can act but need help immediately, for example after slipping on a ladder or when there is a gas leak.

Variant with a repeater gateway: a decision for a real site

Not every pumping station has an internet gateway nearby. The documentation describes a variant in which a LoRa gateway without its own Wi-Fi passes frames through a repeater gateway to a gateway with internet access. Today this solution is only documented, and it is planned as a decision to be implemented only for a real site without full Wi-Fi coverage. We do not promise it as a standard.

In practice, before the pilot the utility should check on the map which sites have internet access and which lie beyond the range of at least one gateway. Only this list shows whether the repeater variant is needed, and for how many sites.

Why the times from deployments matter for a pumping station

For orientation, figures from a working stillness detection deployment are helpful: over 3,400 hours of monitoring, a median alarm closure of 52 seconds, and 7 out of 10 stops are cancelled by the employee alone. These are not data from a pumping station, but from a different environment, and they show that with well-chosen thresholds the alarm does not wear people out.

The pattern for a warning on an LTE watch is simple: 20 seconds without movement gives a warning, a further 30 seconds without a response triggers the alarm, and the SOS button raises the alarm and calls the phone at once. In a pumping station chamber it is usually worth extending these times, because work at a pump is often static. More on choosing thresholds is on the page about stillness thresholds for work in a tank.

What stays with the utility

The system does not replace organisational decisions. The utility must name the people who receive the alarm, decide who goes to the site and within what time, and agree with the dispatch centre what the rescue procedure looks like for wells and chambers. These elements belong in the work instructions, not in the technical configuration.

Nor should one assume that the LoRa scenario has identical paths for every type of device. The exact mapping of the SOS button on radio devices must be confirmed at the design stage for the specific card and bridge type. That is why this article describes a concept, not a specification.

Conclusions for the head of network maintenance

No coverage does not have to mean no supervision. If the LoRa bridge carries the pulses from the active card, the pumping station joins the same stillness and alarm mechanism as the whole utility. Start with a list of sites without connectivity, then check where a gateway with its own network access is enough and where a repeater will be needed.

Video

Frequently asked questions

Does the watch need Wi-Fi for the alarm to reach the system?

No. Pulses from LoRa active cards reach the LoRa bridge, which translates the frames into the existing API. Wi-Fi is not required on the device worn by the employee.

How does stillness differ from SOS?

Stillness is detected automatically and requires the app and the server to agree. A person triggers SOS with a button. It is active and unconditional, does not close itself when movement is detected, and starts the rescue chain.

What if there is no internet gateway near the pumping station?

The documentation describes a variant with a repeater gateway that passes frames to a gateway with internet access. It is an option on request, today only documented, and it is to be decided for a real site.

Is this already deployed at a water utility?

We describe an implementation scenario for a water utility. The stillness mechanism works in other environments, and the figures on times come from such a deployment.

Let's check your sites without coverage

We will go through the list of pumping stations without connectivity with you and show where a LoRa bridge is enough and where the repeater variant will be needed.

Let's talk