InnerWeb
Skip to main content

Vehicle pass at the plant: FAQ for security managers

A security manager asks one question: who opens the gate for a guest or contractor arriving in their own car, and on what basis? Below are the answers to the questions that come up before a vehicle pass rollout, split into what the system checks at the gate and what it does not do.

5 s
window for merging repeated scans of the same code into one event
Source: QR gate function documentation
12 h
stay after which a person without a recorded exit is closed automatically
Source: QR gate function documentation
34 days
maximum range of a single planned visit
Source: planned visits function documentation

What happens at the gate

The most common misunderstanding concerns the act of letting someone in. InnerWeb has no separate button for admitting a person. Scanning the QR code on a badge or the card number is the control itself, and its result decides whether the person enters, exits or is refused.

Does the gate guard have to click anything after the scan?

No. The duty officer scans the code and the security panel shows the verdict. The decision does not depend on whether a tired employee remembers an extra step, and every passage leaves a trace in the register.

Is a blocked attempt also recorded in the register?

Yes. Every scan is saved as a gate entry, including a refusal. The list of people currently on site is therefore a fact from the register, not a guess by the duty officer. During an audit you can show not only who came in, but also who tried to enter and was stopped.

How does the system tell entry from exit?

A second scan of a person who is already on site and has a green verdict records an exit. Two scans of the same code within 5 seconds count as one event, because the scanner can read the same code several times in a fraction of a second, and the second read does not reverse the direction.

Why entry was refused: messages for security

The duty officer at the gate has a few seconds to react, so the message has to be unambiguous and must not require searching through a menu.

What does security see and hear when entry is refused?

When entry is refused, the security panel shows a red banner and plays a voice message in two cases: missing training or missing authorization. Other refusals get only a sound signal. The distinction has a practical purpose: missing training sends the guest to a safety briefing, missing authorization sends them to their host.

Is it enough for a guest to have an invitation?

A planned visit removes only the authorization requirement in the verdict. It acts as a one-day equivalent of an authorization, with no time limit. Training, qualifications and an active account still decide on entry, so an invitation alone does not open the gate for a person without the required safety briefing.

Time limits in the gate register

Time limits in the gate registerBar chart of time limits: 5 s scan merging, 13 s list refresh, 30 s silence, 3 min call window.0102030value in the stated unitMerging scans (s): 5 value in the stated unit5Merging scans (s)Refreshing evacuation list (s): 13 value in the stated unit13Refreshing evacuationlist (s)Silence before group call (s): 30 value in the stated unit30Silence before groupcall (s)Group call window (min): 3 value in the stated unit3Group call window(min)
Source: InnerWeb function documentation: security panel, planned visits, evacuation list

Planned visits and the guest's host

In practice, a vehicle pass starts with a visit planned by an internal employee who is responsible for the guest.

How many days ahead can a visit be planned?

A visit can be planned from today up to 377 days ahead, and no more than 34 days at once. Every visit has a host, meaning an internal employee of the plant. For service visits lasting several days, one planning entry within these limits is enough, instead of registering the guest every morning.

Who gets called when the guest arrives?

When the guest first arrives on the day of the visit, the dispatcher calls the host once, with no retries. A group of guests belonging to one host produces one combined call after 30 seconds of silence within a 3-minute window. If the host has no phone number, the system sends them one email asking them to add the number, instead of staying silent.

What if a contractor arrives without a planned visit?

If the only missing item is the authorization, security can set a visit for today for a person from an external company at the gate. Entry is recorded the same way as a scan. The plant procedure should describe this: who in security has this authority and whom they inform.

System limits: plates and the barrier

Before a plant writes requirements into a tender, it should know the scope of InnerWeb. The feature documentation does not describe reading vehicle registration plates or controlling a barrier. InnerWeb is a software vendor, not a device maker: it does not produce readers or barriers and integrates with the client's existing access control system.

In practice this means a split of responsibilities. The barrier and its controller are supplied by the vehicle access control vendor, while InnerWeb is responsible for the verdict based on training, authorizations and visits, and for the register. Anyone who plans to open the barrier automatically after reading a registration number must write it as a requirement for the barrier vendor and not expect this function from the software.

At a corrugated packaging plant, guests register by phone, sign a health declaration at entry (a BRCGS requirement) and watch a safety video in several language versions, with an assembly point assigned to each group. The same pattern can be extended to a guest arriving by car: registration before the visit shortens the time spent at the gate.

Register and list of people on site

A person who has not recorded an exit is automatically closed after staying longer than 12 hours. The check runs every 3 hours, so a night shift does not stay on the list for hours after work. For the security manager it matters that the list of people present does not contain people who left without an exit record and were cleared only after many hours by the schedule.

The same scans produce the evacuation list: it refreshes every 13 seconds, splits people into six groups (guests, couriers, suppliers, plant employees, external companies, uncertain) and prints on a single page. A vehicle pass is therefore not just a formality at the gate, but also data for use in an incident.

Checklist

Video

Frequently asked questions

Does InnerWeb open the barrier after a scan?

No. InnerWeb does not make barriers and its documentation does not describe controlling them. The gate verdict and the register are on the software side, and opening the barrier is on the side of the client's access control system.

Does the system read registration plates?

The InnerWeb feature documentation does not describe reading registration plates. If the plant needs this, it writes it as a requirement for the vehicle access control vendor.

Is a planned visit enough for a guest to drive in?

Only when the authorization is the only missing item. Training, qualifications and an active account still decide on entry, so a guest without the required safety briefing will be stopped.

What about a guest forgotten in the register after the night shift?

A person without a recorded exit is closed automatically after staying longer than 12 hours, and the check runs every 3 hours. A night shift does not stay on the list for hours.

Let's talk about vehicle passes

We will show how a verdict at the gate looks for a guest arriving by car, on a live security panel. Book a demo with the InnerWeb team.

Let's talk