Checklist: testing the evacuation list a week before a drill

An evacuation drill where the list does not open for the duty officer, or the printout has no group for external companies, ends with a request for a new system rather than a discussion about people. A week before the drill the evacuation coordinator should go through this checklist and test the list on live data.

7 days
recommended test timing before the drill
Source: recommendation
13 s
list refresh interval
Source: function documentation

Purpose and scope of the test

The test answers three questions: does the list show the right people, does the duty officer see it, and can the printout be handed out. The evacuation list is generated from current data on who is present on site, so the test requires that someone actually entered the site that day and scanned the code.

It is best to run the test at peak hours, for example at the start of a shift, because that shows how the list behaves with more people and entries at the same time.

Data on the list

Check whether the six groups contain the people who should be there: some guests, a courier, a supplier, plant employees and an external company. A group with no configured role is described explicitly on the screen and on the printout, so an empty group without a description is a signal to fix the configuration.

Pay attention to people who are missing from the list but should be there: an employee entering through a side door with no gate, or a contractor with an old card. A missing person is more dangerous than an extra one, so this is the first point of the test.

Testing the uncertain group

The list has a separate tab for people with uncertain status. Check whether people with entries and no exit appear there during the test, and whether the duty officer understands that they are people to check.

Testing automatically closed entries

Entries older than 12 hours are closed by a job that runs every 3 hours. Check whether the last run took place within the last three hours.

Evacuation list test time: sample plan (minutes)

Evacuation list test time: sample plan (minutes)Horizontal bar chart: data 15 minutes, access 10, printout 10, conclusions 10 minutes.051015minutesData on the listData on the list: 15 minutes15Access and refreshAccess and refresh: 10 minutes10PrintoutPrintout: 10 minutes10ConclusionsConclusions: 10 minutes10
Source: Sample calculation: time plan for the test

Access and refresh

Check whether everyone who is to use the list during an alarm has access: security, health and safety, the duty officer of the command centre. Access is granted by roles, and each role is checked separately, so the administrator does not inherit security's permissions automatically.

The screen refreshes every 13 seconds. Disconnect the test workstation for a moment and check that the list keeps the last data with a stale-data marker, instead of showing zero people on site.

Printout for the marshals

Print the list on the device you will use during the drill. The printout is one page per group, with the header and footer repeated on every page. Check whether a long group of employees takes several sheets and whether each has a print time.

Hand the sheets to the marshals and ask them to tick off a few people. If a marshal does not know what to do with the uncertain group, add the instruction to the procedure.

After the test: conclusions and fixes

Record the test result in one line: date, number of people on the list, number of discrepancies, person leading the test. Resolve discrepancies before the drill, not after it.

Repeat the test after the fixes. If roles, gates or the group configuration have changed, refresh the instructions for the duty officers as well.

Checklist

Video

Frequently asked questions

How often should the list be tested?

A week before every drill and after every change to the group or gate configuration.

Does the test require stopping the plant?

No. The test runs on current attendance, without interrupting work.

Who should lead the test?

The evacuation coordinator, with security and an IT representative taking part.

What should be done with uncertain people after the test?

Check each person in the tab: establish whether they left, and correct the scanning procedure.

Evacuation drill in a week?

We will go through the checklist with you on your plant's live data and check the printout.

Let's talk