Why a rebuild breaks the coverage
Transmitter coverage depends on the geometry of the metal. BLE range in steel and reinforced concrete structures is verified by measurement on site, so when that geometry changes, an earlier measurement stops being binding. A moved crane may shade a part of the hall that was well covered before, and a new platform may reflect the signal where it did not reflect before.
The second risk lies in the data. During a rebuild, transmitters are sometimes removed and mounted in other places, and the location database is not always updated. The system then keeps assuming that the transmitter hangs where it used to hang.
Route jumps: a symptom of a wrong transmitter position
The route of a vehicle or a worker on the map is a path between the transmitter positions recorded in the database. If a transmitter is recorded in the wrong place, the route draws a jump: the object leaps to the recorded place, although it is physically somewhere else.
A particularly treacherous case is two physically different transmitters with the same identifier. The system recognises them as a single entry, and moving that entry transfers the error to the other place. When transmitters with a repeated identifier appear in the hall after a rebuild, correcting one point breaks the other.
The real position of a transmitter follows from neighbouring points of the route, not from what the system has recorded. That is why the diagnosis does not trust the entry, but compares it with the place where the transmitter actually sits on the traffic route.
Spacing rule: comparison of assumptions before measurement
How to carry out the check after a rebuild
The check starts with a coverage measurement. Coverage measurements are made after installation and attached to the acceptance protocol; after a rebuild they are repeated in the area where the geometry has changed and compared with the earlier result. A drop in the number of audible transmitters at a given place shows that the grid has to be densified.
The second step is a review of the data: the positions of transmitters in the database, the uniqueness of identifiers and their agreement with reality. The third is a test drive or walk along the routes where the structure has changed, observing whether the position on the map jumps. The whole is closed with an entry in the documentation: what was rebuilt, what was measured, what was corrected.
Who is responsible
Most often no owner of this check is named. The rebuild is led by maintenance, the location system is handled by IT or OHS, and nobody connects the two events. The remedy is a written entry in the technical change procedure: every rebuild of a hall or move of a crane triggers a coverage check, and the result goes into the same file as the earlier acceptance protocol.
Checklist
Video
Frequently asked questions
Where does a route jump on the map after a rebuild come from?
Usually from a transmitter recorded in the wrong place in the database. The route is a path between recorded positions, so an error in the record draws a jump.
What if two transmitters have the same identifier?
The system recognises them as one entry, and moving that entry transfers the error to the other place. They need unique identifiers.
How do you know where a transmitter actually is?
The real position follows from neighbouring points of the route, not from the record in the system. It is compared with real movement.
When should the coverage measurement be repeated?
After every change in the metal geometry of the hall, for example after moving a crane or adding a platform.
Let's include coverage control in the procedure
InnerWeb will help you write into the maintenance procedure a check of coverage and transmitter data after every rebuild of a hall.
Let's talk