Why terms, not only price
A system contract runs for several years, and many people who signed it will change positions. A glossary of terms kept in an annex stays, and lets new people read the contract the same way as their predecessors. One agreement meeting before ordering costs less than one dispute over a definition in the third year.
Active user
The licences cover plant users and coordinators of external companies who announce employees; employees of external companies and guests are not counted. The flexible licence costs 80 PLN net per logged-in user per month, with a minimum of 10 users.
Agree with the vendor what logged in during a month means: a single login or a defined amount of working time. The system code has no counter of active users, so counting licences happens outside the system, on the basis of the agreed method. Record the method and the person who passes on the number each month.
Number of terms to tick off in four areas
Stage acceptance
Implementation takes 3 months in three stages, and each stage ends with acceptance of a specific artefact: a working training module, an accepted test permit and a production launch. The concept of acceptance should mean an artefact accepted by the plant, not the vendor's message that it is ready.
Agree who signs the acceptance, within what time the plant reports remarks and what happens after they are reported. Final tests are run on live traffic of external companies, not on test data, so the acceptance criteria must allow time to observe such traffic.
Service window and SLA
The service window is the term agreed with the buyer during which a new version may be downloaded and migrated. The new version is first built and tested by the manufacturer on pre-production. The SLA covers three types of incidents: response 12 hours and repair 8 hours for critical ones, one working day for disruptive ones, and up to 7 days for planned ones.
At the meeting set the weekday and hours of the window, the mode of notifying users and the plant person who approves the date. Also record that outside the window the service tunnel is disabled.
Administrator
On the client side the offer assumes at least 2 system administrators. Agree who they are, how they replace each other and who approves role changes. Details of appointing and securing administrators are set out in a separate checklist for the IT manager.
In the glossary also record the difference between the plant administrator and the service administrator on the manufacturer's side, because they have different permissions and different responsibility for access to the server.
How to run the meeting
The meeting lasts about an hour and is led by the purchasing department together with the IT manager and a representative of the users. It is good to prepare an empty table: term, definition in the contract, plant remarks, responsible person. The result is an annex to the contract, which goes into the archive together with the order.
Checklist
Video
Frequently asked questions
How long does the agreement meeting take?
About an hour, if participants come with a table of terms. The result is an annex to the contract.
Who is counted for licences?
Plant users and coordinators of external companies who announce employees. Employees of external companies and guests are not counted.
What should stage acceptance mean?
An artefact accepted by the plant: a training module, a test permit or a production launch.
Who sets the date of the service window?
The buyer, in agreement with the vendor. Download of the version and migration take place in that window.
Let's talk about the terms of cooperation
We will go through the scope, SLA and purchasing model with you in one meeting. Pricing is individual, and we explain contract terms with examples from the plant.
Let's talk